Abstract
CRPP hosts two unique conductor test facilities SULTAN (SUpraLeiter TestANlage) and EDIPO (European DIPOle). They allow the test of high current superconductors in high magnetic fields (SULTAN 11 T, EDIPO 12.5 T). In both facilities sample currents up to 100 kA can be supplied by means of a NbTi transformer. Presently the facilities are upgraded for the test of high current high-temperature superconductor (HTS) samples. For HTS conductor testing at temperatures between 20 and 50K, the heat flux between the HTS sample under test and the NbTi transformer needs to be limited to around 10W per conductor leg by means of an HTS adapter connecting them. The second required upgrade is the supply of intermediate temperature helium (20-50 K) to the HTS test conductor. It is mandatory that the helium gas coming from the HTS conductor under test can be returned to the cryoplant as cold gas (T < 20K). To reach this goal a tube-in-tube heat exchanger has been manufactured in which 4.5K helium coming from the cryoplant is in counter flow with the warm gas leaving the HTS test conductor.
Published Version
Talk to us