Flash pyrolysis oil from an ENSYN RTP pilot plant was upgraded in a continuous bench scale unit with commercial CoMo and NiMo catalysts in anticipation of scaling up the process. Large amounts of product were produced in a pilot plant for use in an extended analytical characterisation programme.In bench-scale experiments, high deoxygenation rates of 88–99.9% were achieved. Low liquid and high water yields were obtained. The fractionated products of the production run did not fulfil the requirements for direct use as gasoline and diesel.The process is restricted by several operational problems such as rapid catalyst deactivation, coking and plugging. Due to high feedstock and hydrogen addition costs, pyrolysis upgraded oil by the process tested is significantly more expensive than petroleum-derived oil at present oil prices.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.