Abstract

In this research, gold nanoparticles modified choline chloride functionalized graphene oxide (AuNPs-ChCl-GO) was synthesized through the assistance of ultrasound and fabricated as a novel bioelectrochemical sensor and utilized for the sensitive detection of meloxicam (MEL). The morphological and structural features of the AuNPs-ChCl-GO were characterized using different techniques including FTIR, TEM, FE-SEM, EDX, and XRD. The modified electrode showed a remarkable improvement in the anodic oxidation activity of MEL due to the enhancement in the current response compared to the bare carbon paste electrode (CPE). The biosensor composition and measurement conditions were optimized using an experimental design. The differential pulse voltammetry (DPVs) exhibited expanded linear dynamic in the range of 9.0 × 10−9 to 8.5 × 10−7 M for MEL in Britton-Robinson buffer at pH = 4.0 with a detection limit of 1.008 × 10−9 M. The practical utility of the modified electrode was demonstrated by the accurate detection of MEL in human plasma sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.