Abstract
Coal consumption accounted for 36% of America’s CO2 emissions in 2005, yet because coal is a relatively inexpensive, widely available, and politically secure fuel, its use is projected to grow in the coming decades (USEIA, 2007, “World Carbon Dioxide Emissions From the Use of Fossil Fuels,” International Energy Annual 2005, http://www.eia.doe.gov/emeu/iea/carbon.html). In order for coal to contribute to the U.S. energy mix without detriment to an environmentally acceptable future, implementation of carbon capture and sequestration (CCS) technology is critical. Techno-economic studies establish the large expense of CCS due to substantial energy requirements and capital costs. However, such analyses typically ignore operating dynamics in response to diurnal and seasonal variations in electricity demand and pricing, and they assume that CO2 capture systems operate continuously at high CO2 removal and permanently consume a large portion of gross plant generation capacity. In contrast, this study uses an electric grid-level dynamic framework to consider the possibility of turning CO2 capture systems off during peak electricity demands to regain generation capacity lost to CO2 capture energy requirements. This practice eliminates the need to build additional generation capacity to make up for CO2 capture energy requirements, and it might allow plant operators to benefit from selling more electricity during high price time periods. Post-combustion CO2 absorption and stripping is a leading capture technology that, unlike many other capture methods, is particularly suited for flexible or on/off operation. This study presents a case study on the Electric Reliability Council of Texas (ERCOT) electric grid that estimates CO2 capture utilization, system-level costs, and CO2 emissions associated with different strategies of using on/off CO2 capture on all coal-fired plants in the ERCOT grid in order to satisfy peak electricity demand. It compares base cases of no CO2 capture and “always on” capture with scenarios where capture is turned off during: (1) peak demand hours every day of the year, (2) the entire season of peak system demand, and (3) system peak demand hours only on seasonal peak demand days. By eliminating the need for new capacity to replace output lost to CO2 capture energy requirements, flexible CO2 capture could save billions of dollars in capital costs. Since capture systems remain on for most of the year, flexible capture still achieves substantial CO2 emissions reductions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.