Abstract

The tritium storage and delivery system (TSDS) will provide the tritium for high power plasmas in TFTR. TSDS will store tritium as solid uranium tritide at room temperature. At ≳400 °C gas may be released from uranium and pumped through a metal bellows pump to a holding volume. Acceptably pure T2 will be passed along a ∼100‐ft manifold into the storage volumes of three piezoelectric gas injection valves above the torus. Tests on several above components are described. Process components are contained within evacuable housings and three seismically qualified gloveboxes. Two of these boxes are serviced by catalytic oxidation/dessicant adsorption‐based T2 cleanup systems, one of which is dedicated and the other also detritiating torus and neutral beam exhaust gases. TSDS is located in a sealable vault, it is air purifiable by a third such system. Emergency dehumidification of the torus test cell and its basement is also provided. TSDS and the cleanup systems will operate remotely under hardwired interlocks a...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.