Abstract
This paper describes a new facility that has been introduced recently to provide high precision traceable scattering parameter measurements of waveguide devices in the frequency range 140 GHz to 220 GHz (i.e. in waveguide size WR-05). The facility comprises measurement instrumentation situated at the University of Leeds and associated primary reference standards provided by the National Physical Laboratory. The instrumentation consists of a Vector Network Analyzer (VNA) and the standards are precision sections of waveguide that are used to calibrate the VNA. Traceability to national standards and the International System of units (SI) is achieved via precision dimensional measurements of the waveguide sections. Typical measurements, with uncertainties, are given to illustrate the current state-of-the-art for traceable measurements of this type.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.