Abstract
In this study, a new automated noise rejection algorithm, the SOurce-estimate-Utilizing Noise-Discarding algorithm (SOUND), was evaluated on magnetoencephalographic (MEG) resting-state signals in order to select its optimal configuration parameters. Different values of the epoch length and the regularization parameter λ0 were assessed in three scenarios with ascending noise levels. Results show that it is possible to remarkably improve the Signal-to-Noise Ratio, without overly altering the signal of interest. An optimal λ0 value of 0.1 was obtained. However, the epoch length should be adapted to the specific problem. In conclusion, our results suggest that the SOUND algorithm is an appropriate and useful tool to be applied in a preprocessing pipeline for MEG restingstate signals.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.