Abstract

Abstract : This report documents experimental results from a series of experiments using active flow control to improve the performance and efficiency of turbine tip clearance flows. The flow control was based on plasma actuators. Two experimental facilities were used as part of this research project. The first was a low-speed, large-scale turbine cascade using Pak-B turbine blades. The second was a smaller scale, high-speed cascade with low aspect ratio. The active flow control was design to act as a plasma squealer. Specifically, the plasma force was oriented perpendicular to the camber line in order to resist the leakage flow through the tip gap. Both steady and unsteady forcing was used as a method for manipulating natural jet-like instabilities that existed as the leakage flow separated in the tip gap. The results have indicated that the unsteady plasma forcing was as effective as the passive squealer geometry in reducing the losses that occurred in the wake of the blade tip.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.