Abstract

The Time of Flight (TOF) resolution of one of the LHC ALICE detectors, a prototype of the electromagnetic calorimeter PHOS (PHOton Spectrometer), was measured in beam tests carried out at CERN PS. The prototype of the calorimeter consists of 256 ( 22 × 22 × 180 mm 3 ) cells of light-detecting PbWO 4 (PWO) monocrystals read out with 5 × 5 mm 2 Avalanche Photo Diodes (APDs). Three dedicated front end cards with 24 channels of electronics were designed and produced for using in the tests, each channel consisting of one fast and two slow shapers, a time to amplitude converter and three identical 12-bit peak sensitive Analog to Digital Converters (ADCs). The high voltage bias regulator for APD is located on the same card. The measured TOF resolution is described as σ t = 0.24 / E GeV 2 + 0.4 ns .

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.