Abstract

Several types of dry fruits (pistachio nut, dried apricot, almond and raisins) have been investigated for detection of their radiation treatment by gamma rays or electron beam using thermoluminescence (TL) measurements. These samples were irradiated to 1.0–3.0 kGy (gamma rays) or 0.75–3.9 kGy (10 MeV electron beam). Thermoluminescence glow curves for the contaminating minerals separated from the dry fruits were recorded between the temperature range of 50°C and 500°C. In all the cases, the intensity of TL signal for the irradiated dry fruits was 1–3 orders of magnitudes higher than the TL intensity of the corresponding unirradiated control samples allowing clear distinction between the irradiated and unirradiated samples. These results were normalized by re-irradiating the mineral grains with a gamma-ray dose of 1.0 kGy, and a second glow curve was recorded. The ratio of intensity of the first glow curve (TL 1) to that after the normalization dose (TL 2), i.e. (TL 1/TL 2) was determined and compared with the recommended threshold values. These parameters, together with comparison of the shape of the first glow curve, gave unequivocal results about the radiation treatment of the dry fruit samples.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call