Abstract

Five spices, cumin, coriander, clove, cinnamon and black pepper were irradiated by gamma-ray doses of 1.0 and 5.0 kGy and thermoluminescence (TL) method was used for identification of the irradiation treatment. The TL response of the minerals isolated from irradiated samples was much higher as compared to the mineral particles from unirradiated control samples. For the normalisation of results the separated minerals were reirradiated to a normalisation dose of 1.0 kGy and the TL glow curve was recorded a second time. By comparing the glow curves of irradiated and unirradiated samples, finding the ratio of the areas of first and second glow curves (TL1/TL2) and comparing the shapes of the glow curves, all the irradiated and unirradiated samples were identified correctly.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call