Abstract

The whole-body counting (WBC) facility at the Swedish Radiation Safety Authority was rebuilt in a new location during 2004-2007. In this paper, the relocated WBC facility, its background and the detectors' response are described. The report on the limit of detection is given. The report on a first round of measurements on a non-contaminated group of 24 persons for control of Cesium 137 ((137)Cs) and potassium 40 ((40)K) is also presented. The results of the measurements of the control group compared with those from the previous facility revealed biased values up to 5 %, being this more evident for (40)K, which was underestimated. The correction applied and the determination of the measurement uncertainty are described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.