Abstract
With the continued increase in the number of pieces of diagnostic medical radiography equipment being used, radiation shielding in radiology departments is becoming increasingly important. Lead is the most commonly used material for radiation protection; however, there are numerous disadvantages associated with the use of lead, including environmental hazards and harm to the human body. Alternative shielding materials that can be used as replacements include barium sulfate, tungsten, or bismuth. Among alternative materials, barium sulfate appears to be the most cost-effective and easiest to process. In the present study, before constructing shielding barriers, a barrier thickness program for lead-free barrier materials based on National Council on Radiation Protection and Measurements (NCRP) Report No. 147 was used to determine the appropriate barrier thickness. The required thickness for lead-free boards for each type of diagnostic radiography room was calculated based on a tertiary general hospital in the Republic of Korea.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.