Abstract

AbstractA series of paired samples were analyzed to determine if high‐precision lead isotopic fingerprinting could help identify the source of lead in plumbing materials and drinking water. Samples were obtained of plumbing materials (lead service lines, copper pipe with lead solder, galvanized materials, and brass fixtures) from water utilities across the United States. Lead samples were taken from the material itself, from scales, and in some cases from associated water. The lead samples were analyzed to determine the ratios of the four stable lead isotopes present. The results enabled the identification of relationships between various components and further aided in the identification of the source of lead found in water and in pipe scales. Isotopic fingerprinting, as demonstrated in this study, could be used to determine if a galvanized line is a galvanized line requiring replacement (GRR) under the Lead and Copper Rule Improvements (USEPA, 2023).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.