Abstract

The Circular Electron Positron Collider (CEPC) is a proposing electron–positron collider in China, which aims for generating high center-of-mass energy colliding above 250 GeV. The high-granularity electromagnetic calorimeter (ECAL) is included in a calorimeter system, which is mainly responsible for the measurement of photon. A particle flow algorithm (PFA)-based ECAL solution will utilize about 400k channels/m3. Here, we present the design and development status of readout electronics based on SPIROC2b for the CEPC ECAL with high-granularity scintillants and silicon photomultipliers (SiPMs). The readout electronics consists of front-end electronics (FEE), data interface (DIF) board, and data acquisition (DAQ) board. The front-end board (FEB) carries SiPMs (S12571-010P), scintillants (PSD), and FEB application-specific integrated circuit (ASIC) (SPIROC2b). Two electronics were designed in this paper, one is for ASIC functionality and performance only, and the other is used as a single layer of a further prototype of ECAL. Electronic test and cosmic ray test have been done to electronics. The results indicate that a charge dynamic from 62 fC to 300 pC at S/N = 2 is successfully achieved, and the minimum ionizing particles (MIPs) are separated from the pedestal.