SUMMARY Total functional deadspace (including apparatus deadspace) was measured in anaesthetized patients while breathing from masks and after tracheal intubation. The mean VD/VT ratio was 0.18 larger during mask breathing and the mean value for the total functional deadspace was 82 ml greater than in the intubated patients. The results showed an increase in the VD/VT ratio during the inhalation of higher concentrations of halothane: the difference closely approached but did not attain the 95 per cent confidence limit. Values for VD/VT ratio and VD were uninfluenced by the duration of anaesthesia up to 120 minutes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.