Abstract

The effect of energy resolution of two detection systems, HPGe and NaI(Tl), was determined by Monte Carlo (MC) calculation on mass attenuation coefficients of magnesium (Mg) and tungsten (W). In order to reveal the energy resolution effect, the detectors' collimator diameters were changed from 2 mm to 20 mm while sending collimated photon beams to the absorber material. It was observed that mass attenuation coefficients were increased with increasing collimator diameters. The performances of HPGe and NaI(Tl) detectors were quantified. The calculated results were compared with experimental results for Mg at energy of gamma rays 662 keV for different collimator diameters using both HPGe and NaI(Tl). It was observed that the MC calculation results were in a good agreement with the experimental data within the relative error from around 4% to 8%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.