Abstract

We aimed to determine if superb microvascular imaging (SMI) can predict response to uterine artery embolization (UAE) as compared with power Doppler ultrasound. The blood flow and the volume of the dominant leiomyoma was evaluated by power Doppler ultrasonography (PDUS) and SMI 1 day before and 3 months after the UAE procedure. SMI and PDUS blood flow were classified to 4 grades of vascularity. The change in fibroid volume in Grades 0-2 (hypovascular group) was compared to the hypervascular Grade 3 group. Twenty-eight women (mean age, 40.9 years; range, 33-53 years) were examined with PDUS and SMI before and 3 months after UAE. The volume reduction was statistically significantly higher hypervascular group (P < .05). When we accept 30% or more volume reduction as a good response to UAE, the positive predictive value, negative predictive value, sensitivity, specificity, and accuracy of SMI were 100, 64, 73.6, 100, and 82.1%, respectively. There was excellent agreement between the two blinded observers in SMI measurements. SMI, with its high reproducibility, provides further microvessel information than PDUS in uterine fibroids. It may be a useful tool in prediction of response to UAE treatment and improve counseling and patient selection for UAE versus medical or surgical treatment options.