The carry logic module (CLM) is an integral part of a configurable logic block (CLB) in a Xilinx XC4000 field programmable gate array (FPGA). This paper addresses the testing issues of a CLM for the first time. The integrity of a CLM is validated by the integrity of all its components. It has been found that the minimum numbers of CLM test configurations (TCs) under single stuck-at, multiple stuck-at, and universal fault models are six, seven and eight respectively. A set of selection criteria was proposed to obtain the best of eight TCs, each contains a subset of six and seven TCs for the two stuck-at fault models. These CLM TCs can be extended to include the test of the whole CLB.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.