Abstract

Tensile tests were conducted using micro-sized specimens fabricated from constant current and pulse current electroplated Au. The micro-specimens were fabricated by a focused ion beam system and tested by a specially designed micro-mechanical testing machine. Fine-grained electroplated Au was achieved by the pulse current electroplating. Average grain size of the pulse current electroplated Au film was 0.77±0.33μm. Strengthening by grain refinement was observed from the micro-tensile test of the pulse current electroplated Au. The yield stress reached 387MPa. The results obtained in this study followed the Hall-Petch relationship well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.