Abstract
In this study, we proposed a second-order multifunction filter topology based on a current differencing buffered amplifier. With the proposed topology, five filter functions can be realized. Sensitivity and non-ideal state analyses of the proposed circuit have been performed. In addition to the proposed second-order multifunction filter topology, the third-order quadrature oscillator circuit was operated as the application circuit. In both circuits, the theoretical work and simulation results are in compliance. The proposed design has potential in the medical device design field.