Abstract

The purpose of this study was to assess the swine wastewater treatment system, consisting of the anaerobic baffled reactor (ABR), followed by the upflow anaerobic sludge blanket (UASB) reactor at full scale. The system was monitored by analyzing samples collected in the influent and effluent of ABR and UASB. The following parameters were analyzed: temperature, pH, total suspended solids (TSS), volatile suspended solids (VSS), biochemical oxygen demand (BOD), and chemical oxygen demand (COD). Averages of total removal of COD and BOD were 96.7 and 98.4%, respectively. The mean concentrations of COD, BOD, TSS, and VSS at the final effluent were 611, 124, 138, and 134 mg L-1, respectively. The mean volumetric organic loadings (VOL) at the ABR and UASB were 10.29 and 0.99 kg COD m-1d-1. Therefore, the ABR-UASB system was found to be a promising alternative for the swine wastewater treatment.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call