Abstract

A magnetic field has been applied to the 800MHz four-waveguide lower-hybrid heating grill on the Versator II tokamak to suppress plasma formation and RF breakdown in the evacuated waveguides during tokamak operation. Without an auxiliary magnetic field, the incident power density is limited typically to 0.13 kW/cm2. When the imposed magnetic field in the antenna is above the electron-cyclotron resonance value, the grill operates without RF breakdown or plasma formation at an incident power level of 0.42kW/cm2, limited only by the available RF power. A power density of 0.94kW/cm2 has been achieved when all the RF power was injected into one waveguide, again with no evidence of plasma formation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.