Abstract

Addition of gas separation membrane process into the usual tritium removal process from an indoor atmosphere is attractive for a fusion plant, where a large amount of atmosphere should be processed. As a manner to improve the partial pressure difference between feed and permeated side, intended reflux of vapor and the hydrogen concentrated at permeated side is conceived to enlarge the partial pressure difference. Membrane separation with reflux flow has been proposed as an attractive process to enhance the recovery ratio of tritium component. Effect of reflux on the recovery ratio of tritium component was evaluated by numerical analysis. The effect of reflux on separation performance becomes striking as the target species have higher permeability coefficients. Hence, the gas separation by membrane with reflux flow is favorable for tritium recovery.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.