Abstract

In the electric scroll compressor for vehicle air conditioning, the heat generated by motor and inverter is mainly taken away by suction gas. It is necessary to maintain the working temperature of motor and inverter within a safe range to void overheat or burnout. The temperature distribution of motor and inverter under refrigeration conditions are studied using computational fluid dynamics (CFD) simulation in this paper. At first, a CFD fluid-solid coupling simulation model is developed and verified by temperature measurement experiment. The maximum deviation between the simulated temperature at three points on the compressor housing and the measured results does not exceed ±3°C. Then the velocity and pressure distribution of fluid domain, and the temperature distribution of solid domains including the compressor housing, the stator coils and insulated gate bipolar transistor (IGBT) modules are analyzed. Next, the effects of operation conditions on the maximum working temperature and temperature distribution unevenness of stator coils and IGBT modules are discussed in detail. In addition, the working reliability of IGBT modules under refrigeration conditions is checked and the heat dissipation of IGBT modules is analyzed.