Abstract
The size of the 3D micro glass shell resonator is one of the main factors affecting the performance of the micro shell resonator gyroscopes (µSRG) such as resonant frequency and quality factor. Different sizes result in different resonant frequencies, which will directly affect the performance of the µSRG. Therefore, for wafer-level fabrication process of micro shell resonators, ensuring size uniformity is an important issue that must be considered. The original wafer-level method for the preparation of micro shell resonators - chemical foaming process (CFP), cannot guarantee that all the resonators on the wafer have the same size. In this paper, an improved process is investigated to improve size uniformity of wafer level shell resonators. Through the measurement, the standard deviation of the height of micro shell resonators on the wafer is reduced from 0.12 to 0.08, and the range is reduced from 480µm to 350µm. The improved process shows potential for improving size uniformity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.