Abstract
According to the present situation that respirable coal mine dust concentration can not be on-line detected real-timely, a real-time respirable coal mine dust concentration acquisition method that use real-timely detected total coal mine dust concentration combined with calculation of conversion coefficient was put forward. The method obtained respirable coal mine dust concentration through detecting total coal mine dust concentration. First, take use of curve fitting to modify the total dust concentration sensor, and use the modified sensor to detect real-time total dust concentration. Then, conversion coefficient between respirable and total coal mine dust concentration was got through volume calculation method. Finally, the real-time respirable coal mine dust concentration was attained by multiplying the total value and the conversion coefficient. This method was verified in Coal Mine Production Equipment Security Detection Engineering Center of MOE. Experiments proved that respirable coal mine dust concentration obtained by this method had the advantage of high precision. It can meet the requirement of real-time on-line detection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.