Abstract

A study on the Fukushima Daiichi nuclear power station spent-fuel pool (SFP) at Unit 4 (SFP4) is presented in this paper. We discuss the design characteristics of SFP4 and its decay heat load in detail and provide a model that we developed to estimate the SFP evaporation rate based on the SFP temperature. The SFP level of SFP4 following the March 11, 2011, accident is predicted based on the fundamental conservation laws of mass and energy. Our predicted SFP level and temperatures are in good agreement with measured data and are consistent with Tokyo Electric Power Company evaluation results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.