Abstract

The contamination density of 137Cs deposited in the gap between the top and middle covers of the shield plug in the Fukushima Daiichi Nuclear Power Station Unit 2 was estimated using three types of measurement results. Owing to the extremely high dose rate on the entire operation floor, including the top of the shield plug, only remotely measured dose rates, such as ambient dose equivalent rates, were obtained using robots. Based on three types of measurements, significantly higher concentrations of 137Cs were observed than previously estimated. An estimation based on the measurements of the ambient dose equivalent rate inside the hole also demonstrated that the contamination density in the gap between the top and middle covers varied significantly at different positions of the cover. The results obtained will significantly aid in future decommissioning scenarios, and will be important for examining the progress of an accident.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.