Abstract

Many things can affect the Net Plant Heat Rate (NPHR) value, including operating parameters, fuel and equipment’s condition. The performance target of NPHR for Kaltim Teluk CFB CFPP based on specifications is 3430 kCal / kWh. Operational data shows that the NPHR of Unit #1 and Unit #2 is higher then the performance target. Analysis of operation and maintenance data showed that the low average net load and high condenser back pressure are the dominant problems that caused heat loss. One way to minimize heat loss and improve NPHR performance can be done by maximizing debris filter cleaning process through adjusting valve opening angle which can reduce differential pressure and finally reduce the backpressure at the condenser. With the flow simulation inside the debris filter, in order to achieve maximum flow rate with acceptable erosion rate, the optimum cleaning reached at valve opening angle 75°-60° and with this cleaning method, heat loss can be reduced 14.96 kCal/kWh and 50.09 kCal/kWh for unit #1 and unit #2 respectively.