Abstract

Exergy analysis was applied to the evaluation of helium internal purifier in this paper. The important operating parameters has been given to determine the exergy destructions in components as well as in the entire cycle of internal purifier. The analysis results show that the recovery of liquefied air energy can improve the performance of purifier and the exergy destruction of different heat exchanger is different. Results from the analysis helped evolving guidelines for designing appropriate technological process for practical helium internal purifier. An internal purifier with an optimized structure was designed to remove air impurities up to 10 mol%, beyond previous maximum impurity content. The impact on liquefaction capacity is minimized because of the small consumption of cold flow. The achievable performance was also provided in this paper. The purifier could remove air impurities up to 8 mol%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.