Abstract
The paper deals with the speed control of wound rotor induction motor using thyristors in the rotor circuit. It containes two main parts. Firstly it compares the different lossy control methods: connection of thyristors in the secondary side, resistance control by a forced-commutated d.C. chopper and stator voltage control. Secondly it studies in detail the half-controlled bridge connection. The steady-state solution is obtained using approximate methods considering two or four energy storages. The exact solution with six-energy storages is presented and used to study the transient behaviour of the system as well. Experimentally obtained and computed results are compared in an operating point. Die Dr ehzahlregelung von Schleifringläufer-Asynchronmotoren mit Thyristoren im Läuferkreis ist betrachtet. Im ersten Teil werden die verschiedene verlustbehaftete Regelungsmethoden verglichen: Dreiphasenschaltungen der Thyristoren im Läuferkreis; pulsgesteuerter Läuferwiderstand; Drehstromsteller im Ständerkreis. Im zweiten Teil wird die halbgesteuerte Brückenschaltung im Läuferkreis analysiert. Die stationären Betriebsverhältnisse können wohl mit Nëherungsme- thoden berücksichtigend nur zwei bzw. vier Energiespeicher bestimmt werden. Die genaue Lösung mit secns Energiespeiher für die Analyse des dynamischen Verhaltens ist gege-ben. Die gemessene und gerechnete Ergebnisse sind in einem Arbeitspunkt verglichen.