Abstract
This paper presents a new technique for fault detection and isolation to make the traditional vector-controlled induction motor (IM) drive fault tolerant against current and speed sensor failure. The proposed current estimation uses d- and q-axes currents and is independent of the switching states of the three-leg inverter. While the technique introduces a new concept of vector rotation to generate potential estimates of the currents, speed is estimated by one of the available model reference adaptive system (MRAS) based formulations. A logic-based decision mechanism selects the right estimate and reconfigures the system (by rejecting the signal from the faulty sensors). Such algorithm is suitable for different drives, including electric vehicles to avoid complete shutdown of the system, in case of sensor failure. The proposed method is extensively simulated in MATLAB/SIMULINK and experimentally validated through a dSPACE-1104-based laboratory prototype.