Abstract

This report is the outcome of a study of the technical and procedural requirements which would need to be met if the Agency and facility operators were to agree that under certain circumstances the operator could remove or apply on Agency seal in the absence of an inspector. In the FRG and USA Support Programmes respectively an electronic seal (VACOSS) and a CCTV system (MIVS) have been developed. Through a joint project, an interface has been demonstrated which enables the seal data to be superimposed upon the surveillance data. This interface is briefly described in the appendix. A proposed application for this integrated system is to allow facility operators to carry-out some of the seal procedures normally performed by an inspector, thereby reducing the need for inspector presence at certain crucial times.