Abstract

A method has been developed for the separation and measurement of ethylene glycol and three other glycols (propylene glycol, 1,3-butylene glycol and 2,3-butylene glycol) in biological samples by wide-bore column gas chromatography with a flame ionization detector. The method used 1,3-propylene glycol (1,3-propanediol) as an internal standard. The method was linear at least from 2 to 1000 μg/ml, with a detection limit of 1 μg/ml. Analytical recoveries were 89–98% for the different concentrations. Precision studies showed coefficients of variation of 1.5–7.7% for the different concentrations. The assay was applied to the analysis of biological samples from two patients who had ingested ethylene glycol and/or other glycols in a suicide attempt.