Abstract

A simple and sensitive high-performance liquid chromatographic method was developed for the determination of sildenafil transdermal permeation of nude mouse skin. A reversed-phase column with UV detection at 224 nm was used for chromatographic separation. The mobile phase consisted of 32% acetonitrile with 0.2% phosphoric acid in water at pH 5.3 adjusted with 10 M NaOH with the flow-rate set at 1.0 ml/min. The limit of quantitation achieved was 5 ng/ml, and the calibration curve showed good linearity over the concentration range of 5–500 ng/ml. The relative standard deviations of within- and between-day analyses were all within 15%. Sildenafil was found to be stable between pH 3 and 12 during 24-h incubation with skin. After transdermal administration of 15.8 μg/ml of sildenafil to nude mouse skin, it was detected as early as 15 min. The transport amount of sildenafil could be quantitated and, at pH 8–11, had the highest permeation rate in nude mouse skin.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.