Abstract

Complete upper airway obstruction by a foreign body is adramatic and acute emergency situation, and can result in rapid development of hypoxia, circulatory arrest and death. Special Magill pliers with an adjustable video optical system have been developed for airway inspection to facilitate efforts to remove foreign bodies causing obstruction of the upper airway. To remove asimulated airway foreign body from acardiopulmonary resuscitation (CPR) manikin, either with normal Magill pliers or with the newly designed video Magill pliers. After abrief introduction, 81kindergarten teachers, 51pupils (age 10-14years) and 52prospective emergency physicians were asked to remove a2 × 2 "Lego" brick from the hypopharynx of aCPR manikin using either standard Magill pliers or the newly designed video Magill pliers. The formal hypothesis was that there would be no differences between the methods. Successful removal was defined as when the first removal attempt resulted in the Lego brick passing beyond the teeth of the manikin within 60s. The use of the video Magill pliers resulted in significantly higher success rates in removal of the simulated foreign airway body within 60 s compared to standard Magill pliers in kindergarten teachers (84% vs. 30%, p < 0.0001), pupils (84% vs. 18%, p < 0.0001) and prospective emergency physicians (92% vs. 40%, p < 0.0001). The time needed for removing the foreign airway body was significantly shorter in groups using the video Magill pliers (kindergarten teachers 29 ± 18s vs. 45 ± 19 s, pupils 29 ± 18s vs. 54 ± 14 s, and prospective emergency physicians 33 ± 18s vs. 45 ± 20 s; p < 0.0001). In an analogue points system (from 1 very simple to 10 extremely complicated), the user friendliness of the video Magill pliers was judged to be significantly higher than the standard Magill pliers (2.8 ± 1.6 vs. 7.8 ± 2.7 kindergarten teachers, 2.0 ± 1.3 vs. 7.2 ± 2.5 pupils and 3.2 ± 2.2 vs. 4.9 ± 3.1 prospective emergency physicians, p < 0.0001). Visibility of the airway foreign body was estimated to be significantly better employing the video Magill pliers compared to the standard Magill pliers (1.9 ± 1.4 vs. 9.8 ± 0.6 kindergarten teachers, pupils 1.3 ± 0.6 vs. 9.2 ± 1.6, prospective emergency physicians 2.3 ± 1.8 vs. 9.1 ± 2.3, p < 0.0001). In this study kindergarten teachers, pupils (aged 10-14 years) and prospective emergency physicians had higher success rates in less time and reported better user friendliness and visibility using video Magill pliers compared to standard Magill pliers for removing asimulated foreign body from aCPR manikin airway.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.