Abstract
A sensitive high-performance liquid chromatographic method is described for the quantification of midazolam and 1′-hydroxymidazolam in human plasma. Sample (1 ml plasma) preparation involved a simple solvent extraction step with a recovery of approximately 90% for both compounds. An aliquot of the dissolved residue was injected onto a 3 μm capillary C 18 column (150 mm×0.8 mm I.D.). A gradient elution was used. The initial mobile phase composition (phosphate buffer–acetonitrile, 65:35) was maintained during 16 min and was then changed linearly during a 1-min period to phosphate buffer–acetonitrile, 40:60. The flow-rate of the mobile phase was 16 μl/min and the eluate was monitored by UV detection. The limits of quantification for midazolam and 1′-hydroxymidazolam were 1 ng/ml and 0.5 ng/ml, respectively. The applicability of the method was demonstrated by studying the pharmacokinetics of midazolam, and its major metabolite 1′-hydroxymidazolam, in human volunteers following i.v. bolus administration of a subtherapeutic midazolam dose (40 μg/kg).
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.