Abstract

The subject of this paper is an experimental and numerical analysis of the stability of the wall panels with one-side board sheathing for timber structures. The reinforcement of the panel is provided using glued timber composite I-shaped element consisting of a web made of a wood-based desk embedded into flanges of solid timber. The mechanism of the behaviour of these panels, mode of the failure and reliable procedure to determine the buckling load-bearing capacity not been fully explored so far. This work describes the behaviour of the wall panel under vertical load and the method of failure using experimental and numerical analysis. The reduction coefficient kJ was determined, which can be used for a simple calculation of the buckling capacity of a wall panel.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.