Abstract

Exergy analysis is a powerful tool to determine inefficiencies of a process and to evaluate the performance. The reverse osmosis (RO) plant of Al-Hussein thermal power station was analyzed thermodynamically using actual plant data. Exergy flow rates are evaluated throughout the plant. The rates of exergy destruction and their percentages are calculated so that the locations of highest exergy destruction can easily be identified. The highest exergy destruction (56.8%) occurs within the throttling valves followed by the exergy destruction in the two-stages RO units (about 21%). The exergy destruction in the pumps and motors account for 19.6% of the total. The second law efficiency of the plant is very low, 4.1%. This indicates that opportunities of improvement exist to reduce exergy destruction and make the plant operation more cost effective. This may include the use of high-efficiency pump/motor set-up with a variable frequency drive and the replacement of the traditional throttling valves with energy recovery devices such as pressure exchangers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.