Abstract

In the current study, the effect of corundum particle sizes (50 and 250–320 μm) used for sand–blasting on the structure, roughness, wettability, mechanical properties, and adhesion of radio frequency magnetron hydroxyapatite coating deposited on treated titanium substrate is studied. Morphology analysis revealed that pretreatment uniformly deforms the surface and induces the formation of pits, which size depends linearly on the grit size. The deposited coatings (Ca/P was in a range of 1.75-1.79) are homogeneous and repeat the relief of the substrate (mean roughness Ra is 1.9±0.1 (250–320 μm) and 0.8±0.1 μm (50 μm)). Texture coefficient calculations revealed the predominant (002) growth texture of hydroxyapatite coatings. The resistance of the coating to plastic deformation and the surface hardening were significantly higher for coatings formed on sand blasted with particle size of 50 μm. Scratch test have shown the significant improvement of wear resistance and lower friction coefficient of coatings for smoother samples. Dynamic contact angle measurements revealed the hydrophilic properties of the hydroxyapatite coating. Thus, sand–blasting of titanium with corundum powder having the size of 50 μm prior to the deposition of RF magnetron coating is recommended for the medical applications intended to improve the bonding between the substrate and coating.

Highlights

  • Our previous study have assessed the effects of SB at different pressures on grain size, mechanical properties and surface wettability of radio frequency (RF) magnetron silver-containing HA coating and revealed that the coating microstructure could be designed by controlling the pre-treated Ti surface topography

  • The type, size and geometry of the sand particles are important factors determining the result of the treatment

  • In the current study, the effect of SB particle size (50 and 250–320 μm) on the surface structure, roughness, wettability, mechanical properties, and adhesion failure at the interface of radio frequency (RF) magnetron deposited HA coating is studied

Read more

Summary

Introduction

SAND-BLASTING TREATMENT AS A WAY TO IMPROVE THE ADHESION STRENGTH OF HYDROXYAPATITE COATING ON TITANIUM IMPLANT

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.