Control strategies for extracting the three-phase reference currents for shunt active power filters are compared, evaluating their performance under different source voltage conditions in MATLAB/Simulink environment and also with Real Time Digital Simulator (RTDS) Hardware. When the supply voltages are balanced and sinusoidal, then all control strategies converge to the same compensation characteristics. However, when the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different degrees of compensation in harmonics. The p-q control strategy unable to yield an adequate solution when source voltages are not ideal. Extensive Simulations are carried out with Fuzzy Controller for both p-q and Id-Iq control strategies for different voltage conditions and adequate results were presented. The 3-ph 4-wire SHAF system is also implemented on a RTDS Hardware to further verify its effectiveness. The detailed simulation and RTDS Hardware results are included.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.