Abstract
Background: Mechanical ventilation is lifesaving in children with respiratory failure. However, its unnecessary prolongation once a child is capable of sustaining spontaneous effective ventilation is associated with significant complications. Objective: To identify the factors that lead to higher chance of extubation failure in mechanically ventilated children. Materials and Methods: A prospective, observational study was conducted over a period of 1 year. Children admitted to pediatric intensive care unit of a tertiary care hospital of Northern India aged 1 month–17 years, needing mechanical ventilation were included in the study. Predefined criteria were used to decide the timing of extubation. Relevant details were recorded to study various patient-related parameters and their association with extubation outcome. Results: Mean age of the study group was 50 months with a male:female ratio of 3:1. Extubation failure rate was 14.5%. Extubation failure was significantly higher in patients ventilated for >7 days (p=0.01), those with the pediatric risk of mortality score >10 at admission (p=0.009), in addition to peak inspiratory pressure >16 cm H2O (p=0.009) and FiO2 ?0.35 (p=0.01) before extubation. Accidental extubation was also associated with higher extubation failure (p<0.001). Conclusion: Our study demonstrates that even though sicker patients requiring ventilation for longer duration are more prone to failed extubations, protocol based, and planned extubations lead to better extubation success.
Published Version (
Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have