Abstract
Experimental vibration-fatigue tests were conducted with sine resonance track‐and‐dwell (SRTD) tool by using an electrodynamic shaker on specimens made of 304L stainless steel. Due to cyclic fatigue resulting in stiffness loss, it can be found that the resonant frequency decreases when the specimen experiences substantial crack growth, especially for out-of-plane bending mode. The specimens were equipped by a crack propagation gauge (CPG) to monitor the crack growth. However, the presence of crack was detected late by these gauges. The deviation of the resonance frequency was therefore analysed from the time response measurements, and the results were confronted to the CPG measurements to conclude on the validity of the detection threshold provided by the literature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.