Abstract

This article investigates the failure due to collapse of the MEMS beams in capacitive MEMS power sensor based on GaAs MMIC process. Generally, the residual stress and adhesion are the main causes of the collapse of the MEMS beams. So, this article investigates the residual stress of the MEMS beams with an improved rotating technique. In addition, a resonant method has been used to investigate the adhesion of the MEMS beams. The measurement result shows that the buckling due to the residual stress is very small. Also, the finite analysis results show the rotating angle θ should be less than 0.12°. Thus, the collapse of the MEMS beams is mainly caused by adhesion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.