Abstract

AbstractThe effect of a post plasma treatment on the dielectric properties and reliability of fluorine doped silicon oxide (SiOF) films deposited by electron cyclotron resonance chemical vapor deposition (ECRCVD) was studied. Also, the thermal stability of an electrodeposited Cu / sputtered Ta interconnect system with SiOF intermetal dielectrics was examined by annealing in a vacuum furnace. The stability of the dielectric constant of SiOF films was improved by O2 post plasma treatment. Surface modification by the plasma treatment was effective in prevention of water absorption. The Cu/Ta/SiOF/Si system was thermally stable at least up to 500°C for 3h. For the Cu/Ta/SiOF/Si multilayer structure, the plasma treatment seemed to play a big role in suppressing the interdiffusion between SiOF and metal interconnects. By C-V measurement, the electrical stability of the Cu/Ta/SiOF/Si multilayer structure was found to be stable up to 500°C for 2 h.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.