Abstract

This research was conducted on inseptisol soils, especially for vegetable plantations, aimed to determine the ability of the soil layer to distribute nutrients and restore soil health and fertility due to the use of chemical fertilizers and pesticides. Through microbial activity that is controlled by spreading through a horizontal biohole, this study observes in real time through a micro controller the changes in soil acidity, infiltration rate, electrolyte conductivity levels and porosity levels through soil infiltration rates. Through simulations with the variable microbial population, it can be seen the level of EC and other parameters against the time of observation in real time. From the observations of graphs and EC standards, it can be seen that the ability of the soil. Until day 45 the soil fertility level has not reached=1500 uS/cm with a microbial population=103/cfu. Support the planting schedule both during the vegetative growth period and during the generative growth period, so that we will know when the right time to do is: Soil recovery, initial planting and when the tubers/flowers/fruit begin to be conditioned. until cooked based on nutrient values observed through sensors that convert analogue parameters by the micro controller into digital information transmitted by Wi-Fi in real time. The initial condition before simulating the soil fertility value with the Electrolyte Conductivity (EC) parameter is 744 uS/cm, the simulation results are: Simulation A: To start the growth period (vegetative) is achieved on the 15th day with a EC E=1050 uS/cm and in the generative period it is reached on the 23th day with a EC=1518 uS/cm. Simulation B: To start the growth period (vegetative) is achieved on the 22th day with a EC=1008 uS/ cm and at the generative period it is reached on the 38nd day with a EC=1539 uS/cm . Simulation C: to start the growth period (vegetative) is achieved on day 37 with a EC=1025 uS/cm and during the generative period it cannot be observed because on observation until day 45 the electrolyte conductivity has not reach=1500 uS/ cm.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call