Abstract

A rapid, sensitive and reproducible HPLC method was developed and validated for the analysis of adefovir (CAS 106941-25-7) in human plasma. The separation was achieved on a monolithic silica column (Chromolith Performance RP-18e, 100 x 4.6 mm) using acetonitrile-ammonium dihydrogen phosphate buffer (6:94, v/v), pH 5.2, as the mobile phase at a flow rate of 1.5 ml min(-1). The wavelength was set at 260 nm. The assay enables the measurement of adefovir for therapeutic drug monitoring with a minimum quantification limit of 1 ng ml(-1). The method involves a simple protein precipitation procedure. Analytical recovery was complete. The calibration curve was linear over the concentration range 1-40 ng ml(-1). The coefficients of variation for inter-day and intra-day assay were found to be less than 5%. The method was applied to the determination of adefovir in plasma from 12 subjects dosed with adefovir 2 x 10 mg tablets and pharmacokinetic parameters were evaluated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.