Abstract

A rapid and sensitive chiral high-performance liquid chromatographic (HPLC) assay for the simultaneous determination of salmeterol and its principal human metabolite α-hydroxysalmeterol is described. The two pairs of enantiomers were resolved on a chiral-cellobiohydrolase column and detected by electrochemical detection at +700 mV. Standard curves were linear over the concentration range 0.1 to 4.0 μ M for α-hydroxysalmeterol enantiomers and 2.5 to 40.0 μ M for salmeterol enantiomers. Intra- and inter-day coefficients of variation were <10%. The method was applied to a study of human hepatic metabolism in vitro which showed that microsomal metabolism of salmeterol to α-hydroxysalmeterol is not stereoselective.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.