Abstract
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of midazolam, 8-chloro-6-(2-fluorophenyl)-1-methyl-4H-imidazo[1,5-a][1,4]-benzodiazepine (I), and its four metabolites in plasma. The assay involves extraction into diethyl ether—methylene chloride (7:3) from plasma buffered to pH 9 and subsequent analysis by reversed-phase HPLC with ultraviolet detection at 254 nm. The overall recovery of I from dog plasma was 94.5 ± 7.1% and > 89.0% for its metabolites. The sensitivity limit of the assay was 50 ng/ml of plasma for all compounds. The HPLC assay was used to determine plasma concentrations of I and its metabolites from selected samples taken from an oral toxicity study in the dog.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.